think…mercer first®
Features:
- Designed with "Auto Seat Technology"®
- A low rated and fully guided spring allows for more consistent Set Pressures from pop to pop.
- Consistent Set Pressures allows for repeatable use without the need for excessive repairs or resetting.
- Open, Close, Seat and Seal™
- Non-rising stems allowing valves to be installed in small areas.
- Pilot Valve options include: Backflow Preventer, Pressure Snubber and Auxiliary Filter.
- Modulating Pilot Valve options include: Field Test Connection, Test Gag, and Manual or Remote Blowdown.
- Sour Service Trim available.
- Additional options available to meet NACE MR0175 requirements.
- Canadian Registration Number (CRN)
- Additional options available to meet Conformité Européenne (CE) to PED Directive 2014/68/EU and/or ATEX Directive 2014/34/EU
Orifice | L (USC) | L (SI) |
---|---|---|
OrificeStandard Inlet Sizes | L (USC) 3", 4" | L (SI) DN 80, DN 100 |
OrificeInlet and Outlet Connection Types | L (USC) RF x RF, RTJ x RF, RTJ x RTJ | L (SI) RF x RF, RTJ x RF, RTJ x RTJ |
OrificeActual Orifice Diameter | L (USC) 2.020 in | L (SI) 51.3 mm |
OrificeActual Orifice Area | L (USC) 3.205 in2 | L (SI) 2067.7 mm2 |
OrificeAPI Orifice Area | L (USC) 2.853 in2 | L (SI) 1840.6 mm2 |
OrificePressure Range | L (USC) 15 – 1480 psig | L (SI) 103 – 10204 kPag |
OrificeStandard Temperature Range | L (USC) -20°F to 400°F | L (SI) -29°C to 204°C |
OrificeASME Flow Coefficient, Kd (Gas) | L (USC) 0.870 | L (SI) 0.870 |
Mercer Valve Co., Inc. reserves the right to change product designs and specifications without notice.
9500 Modulating Main Valve "L" Orifice | Part Number Selection
A | INLET & OUTLET COMBINATION
B | API ORIFICE SIZE
C | FLANGE TYPE
D | BODY MATERIAL
E | OPTIONS
F | SEAT MATERIAL┼┼
G | SOUR GAS SERVICE
H | PILOT TYPE
I | O-RING MATERIAL┼┼
J | TWO-DIGIT "SPECIAL" CODE
★Standard Materials or Options.
┼┼O-ring codes are only used with Seat codes 7, 9, & Y when O-rings are not standard FKM. If using the standard FKM O-rings, leave O-ring code BLANK.
9500 Modulating Pilot Valve | Part Number Selection
A | MODULE PRESSURE CODE
B | BODY MATERIAL
C | MODULE SEALS▼
D | BLOWDOWN TYPE
E | FIELD TEST CONNECTION
F | TEST ACCESSORIES
G | SPRING CODE
H | SOUR GAS SERVICE
I | ORING MATERIAL▼
J | TWO-DIGIT "SPECIAL" CODE
★Standard Materials or Options.
▼Module Seal codes 2, 3, 4 & 5 receive like material O-rings and Exhaust Seats. Consult Factory.
╋May require a Special Code on the Main Valve. Consult Factory.
Inlet and Outlet Code | Inlet and Outlet Size (in) | Pressure Limit 1, 2 (psig) | Dimensions 2 "A" x "B" x "C" (in ± .062) | Approximate Weight 2 (lbs) |
---|---|---|---|---|
Inlet and Outlet Code62☆ | Inlet and Outlet Size (in) 3" 150 x 4" 150 | Pressure Limit 1, 2 (psig)285 | Dimensions 2 "A" x "B" x "C" (in ± .062) 6.125 x 6.375 x 18.898 | Approximate Weight 2 (lbs) 104 |
Inlet and Outlet Code64☆ | Inlet and Outlet Size (in) 3" 300 x 4" 150 | Pressure Limit 1, 2 (psig)740 | Dimensions 2 "A" x "B" x "C" (in ± .062) 6.125 x 6.375 x 18.898 | Approximate Weight 2 (lbs) 107 |
Inlet and Outlet Code65☆ | Inlet and Outlet Size (in) 3" 600 x 4" 150 | Pressure Limit 1, 2 (psig)1425 | Dimensions 2 "A" x "B" x "C" (in ± .062) 6.375 x 6.375 x 19.148 | Approximate Weight 2 (lbs) 109 |
Inlet and Outlet Code65.1 | Inlet and Outlet Size (in) 3" 600 x 4" 300 | Pressure Limit 1, 2 (psig)1480 | Dimensions 2 "A" x "B" x "C" (in ± .062) 7.500 x 7.125 x 20.273 | Approximate Weight 2 (lbs) 124 |
Inlet and Outlet Code66.1☆ | Inlet and Outlet Size (in) 3" 900 x 4" 300 | Pressure Limit 1, 2 (psig)1480 | Dimensions 2 "A" x "B" x "C" (in ± .062) 7.500 x 7.125 x 20.273 | Approximate Weight 2 (lbs) 134 |
Inlet and Outlet Code66.2☆ | Inlet and Outlet Size (in) 3" 1500 x 4" 300 | Pressure Limit 1, 2 (psig)1480 | Dimensions 2 "A" x "B" x "C" (in ± .062) 7.500 x 7.125 x 20.335 | Approximate Weight 2 (lbs) 148 |
Inlet and Outlet Code66.3 | Inlet and Outlet Size (in) 3" 1500 x 4" 600 | Pressure Limit 1, 2 (psig)1480 | Dimensions 2 "A" x "B" x "C" (in ± .062) | Approximate Weight 2 (lbs) |
Inlet and Outlet Code70☆ | Inlet and Outlet Size (in) 4" 150 x 6" 150 | Pressure Limit 1, 2 (psig)285 | Dimensions 2 "A" x "B" x "C" (in ± .062) 7.750 x 8.250 x 21.104 | Approximate Weight 2 (lbs) 153 |
Inlet and Outlet Code71☆ | Inlet and Outlet Size (in) 4" 300 x 6" 150 | Pressure Limit 1, 2 (psig)740 | Dimensions 2 "A" x "B" x "C" (in ± .062) 7.750 x 8.250 x 21.104 | Approximate Weight 2 (lbs) 162 |
Inlet and Outlet Code72☆ | Inlet and Outlet Size (in) 4" 600 x 6" 150 | Pressure Limit 1, 2 (psig)1480 | Dimensions 2 "A" x "B" x "C" (in ± .062) 7.750 x 8.250 x 21.104 | Approximate Weight 2 (lbs) 226 |
Inlet and Outlet Code73.1☆ | Inlet and Outlet Size (in) 4" 900 x 6" 300 | Pressure Limit 1, 2 (psig)1480 | Dimensions 2 "A" x "B" x "C" (in ± .062) 9.813 x 9.188 x 23.167 | Approximate Weight 2 (lbs) 226 |
Inlet and Outlet Code73.2☆ | Inlet and Outlet Size (in) 4" 1500 x 6" 300 | Pressure Limit 1, 2 (psig)1480 | Dimensions 2 "A" x "B" x "C" (in ± .062) | Approximate Weight 2 (lbs) |
1Pressure limit may be subject to system conditions and temperatures.
2Pressure limit, weight, and “C” dimension may vary with sour gas service and other options.
☆Flange dimensions compliant with API 526.
Inlet and Outlet Code | Inlet and Outlet Size DN (mm) | Pressure Limit 1, 2 (kPag) | Dimensions 2 "A" x "B" x "C" (mm ± 1.6) | Approximate Weight 2 (kg) |
---|---|---|---|---|
Inlet and Outlet Code62☆ | Inlet and Outlet Size DN (mm)DN 80 150 x DN 100 150 | Pressure Limit 1, 2 (kPag)1965 | Dimensions 2 "A" x "B" x "C" (mm ± 1.6)155.6 x 161.9 x 384.2 | Approximate Weight 2 (kg)47.2 |
Inlet and Outlet Code64☆ | Inlet and Outlet Size DN (mm)DN 80 300 x DN 100 150 | Pressure Limit 1, 2 (kPag)5102 | Dimensions 2 "A" x "B" x "C" (mm ± 1.6)155.6 x 161.9 x 384.2 | Approximate Weight 2 (kg)48.5 |
Inlet and Outlet Code65☆ | Inlet and Outlet Size DN (mm)DN 80 600 x DN 100 150 | Pressure Limit 1, 2 (kPag)9825 | Dimensions 2 "A" x "B" x "C" (mm ± 1.6)161.9 x 161.9 x 390.5 | Approximate Weight 2 (kg)49.4 |
Inlet and Outlet Code65.1 | Inlet and Outlet Size DN (mm)DN 80 600 x DN 100 300 | Pressure Limit 1, 2 (kPag)10204 | Dimensions 2 "A" x "B" x "C" (mm ± 1.6)190.5 x 181.0 x 419.1 | Approximate Weight 2 (kg)56.2 |
Inlet and Outlet Code66.1☆ | Inlet and Outlet Size DN (mm)DN 80 900 x DN 100 300 | Pressure Limit 1, 2 (kPag)10204 | Dimensions 2 "A" x "B" x "C" (mm ± 1.6)190.5 x 181.0 x 419.1 | Approximate Weight 2 (kg)60.8 |
Inlet and Outlet Code66.2☆ | Inlet and Outlet Size DN (mm)DN 80 1500 x DN 100 300 | Pressure Limit 1, 2 (kPag)10204 | Dimensions 2 "A" x "B" x "C" (mm ± 1.6)190.5 x 181.0 x 419.1 | Approximate Weight 2 (kg)67.1 |
Inlet and Outlet Code66.3 | Inlet and Outlet Size DN (mm)DN 80 1500 x DN 100 600 | Pressure Limit 1, 2 (kPag)10204 | Dimensions 2 "A" x "B" x "C" (mm ± 1.6) | Approximate Weight 2 (kg) |
Inlet and Outlet Code70☆ | Inlet and Outlet Size DN (mm)DN 100 150 x DN 150 150 | Pressure Limit 1, 2 (kPag)1965 | Dimensions 2 "A" x "B" x "C" (mm ± 1.6)196.9 x 209.6 x 441.3 | Approximate Weight 2 (kg)69.4 |
Inlet and Outlet Code71☆ | Inlet and Outlet Size DN (mm)DN 100 300 x DN 150 150 | Pressure Limit 1, 2 (kPag)5102 | Dimensions 2 "A" x "B" x "C" (mm ± 1.6)196.9 x 209.6 x 441.3 | Approximate Weight 2 (kg)73.5 |
Inlet and Outlet Code72☆ | Inlet and Outlet Size DN (mm)DN 100 600 x DN 150 150 | Pressure Limit 1, 2 (kPag)10204 | Dimensions 2 "A" x "B" x "C" (mm ± 1.6)196.9 x 209.6 x 441.3 | Approximate Weight 2 (kg)77.6 |
Inlet and Outlet Code73.1☆ | Inlet and Outlet Size DN (mm)DN 100 900 x DN 150 300 | Pressure Limit 1, 2 (kPag)10204 | Dimensions 2 "A" x "B" x "C" (mm ± 1.6)233.4 x 233.4 x 495.3 | Approximate Weight 2 (kg)115.7 |
Inlet and Outlet Code73.2☆ | Inlet and Outlet Size DN (mm)DN 100 1500 x DN 150 300 | Pressure Limit 1, 2 (kPag)10204 | Dimensions 2 "A" x "B" x "C" (mm ± 1.6) | Approximate Weight 2 (kg) |
1Pressure limit may be subject to system conditions and temperatures.
2Pressure limit, weight, and “C” dimension may vary with sour gas service and other options.
☆Flange dimensions compliant with API 526.